Technical Description
  • Rectangular (R) or square (Q) galvanised steel panels, thickness mm. 0,6.
  • Rectangular panel size: from mm 300x600 to mm. 600x1500, standard size mm. 300x1200 - mm. 600x1200.
  • Square panel size: from mm 300x300 to mm. 750x750, standard size mm. 600x600.
  • Hidden structure formed by main slotted profile and clip-type secondary profile.
  • Powder painting 70-80 microns.
  • Standard col. Ral 9010.
  • Minimum air space overall dimensions: mm. 100.

System features
  • Ready to deliver for standard models.
  • It can be used in the most varied configurations and enviromental dimensions.
  • Simple and fast fitting of the panels.
  • Full inspection possibility of the hollow space by lid-release of each single panel. The inspection is made easier by the panel sliding and the clip profile.

Sound-proofing
Sound-proofing:
horizontal, by the insertion of soundproof panels on the whole surface of the false ceiling.
Vertical: by inserting plaster/paper sound-proof baffles at the walls. 
Acoustic absorption:
different holes (see table) are available to the purpose, making the false ceiling soundproof together with soundproofing materials: specially suitable is the black Soundtex "paper tissue" film that dramatically reduces reverberation time and noise levels in general (see acoustic certifications).
 


 
Data sheet
CLIP-IN ACCESS SYSTEM